10 •
CAUTION!
Patient hazard, malfunction
• Keep other medical devices, e.g. high-frequency surgical
devices, at a minimum distance of approx. 1 meter to prevent
incorrect measurement or faults with wireless transmission.
• Keep HF devices such as cell phones at a minimum distance of
approx. 1 meter to prevent incorrect measurement or faults with
wireless transmission.
Preventing electric shock WARNING!
Electric shock
• Never touch the power supply with wet hands.
• Do not use an extension cable and multiple outlets. This also
applies for the USB connection on the touchscreen display.
• Make sure that the power cable is not crimped and cannot be
damaged by sharp edges.
• Do not operate the device above a height of 3000 m.
Preventing injuries and infections WARNING!
Patient hazard
• Prepare the device hygienically after each measurement (see
“Hygienic preparation” on page 64).
• Ensure that the patient does not have any contagious diseases.
• Ensure that the patient does not have any wounds on the palms
on their hands or the soles of their feet.
• Ensure that the positioning of the device is steady and even.
• The device is not designed to be a stand assist. Assist people
with limited mobility, e.g. when they are sitting up from a
wheelchair.
• Ensure that the weighing platform is dry before the patient steps
onto it.
• Ensure that the patient has dry feet before they step onto the
weighing platform.
• Ensure that the patient does not step directly onto the edges of
the weighing platform.
• Ensure that the patient steps onto the weighing platform slowly
and safely.
• Route the network and power cable such that no one can trip
over them.
Preventing device damage ATTENTION!
Damage to device
• Make sure that fluids never get inside the device. These can
destroy the electronics.
Switch off the device before you disconnect the power pack from
the power supply.
If device is not be used for a longer period of time, disconnect the
power pack from the power supply. Only then is the device out of
operation.
• Do not let the device fall.
• Do not subject the device to heavy jolts or vibrations.
• Do not place the device in direct sunlight and make sure that it is
not placed in direct proximity of a heat source. High temperatures
could damage the electronics.
• Avoid rapid temperature fluctuations. If the device is transported
where a temperature difference of more than 20 °C occurs, the
device must be left alone for two hours before it is switched back
on. Otherwise, condensate may form; this can damage the
electronics.